FF-T 316L trefoil cable cleats for project power routes
The FF-T family is intended for three single-core cables in a trefoil formation. Match each cable’s actual outside diameter to the selected catalogue size and current drawing. The verified dimensional examples and company cable-cleat catalogue are provided below.
Review the liner, closure parts, mounting hole, fixing hardware and support arrangement with the quotation. The family code does not identify one size or one short-circuit rating.
Certifications and Test Reports Available
Younxin can provide certification and test documentation for project procurement and technical review.
DNV / ABS Approvals
Approval documentation is available for applicable cable-cleat models. Confirm the certificate scope for the proposed model with your quotation.
IEC 61914 Test Reports
STIEE short-circuit test reports are available for the tested trefoil and quad cable-cleat assemblies.
Intertek Test Reports
UV-aging and needle-flame test documentation is available for the stated sample models.
Certificates and complete test reports are provided on request. Confirm the covered model, assembly and installation conditions for your project.
Request certificates and test reports
Choose the cleat from the power-cable route
For oil and gas projects, identify process-plant, LNG utility, coastal-terminal or offshore-module exposure and send the corrosion specification with the electrical cable schedule. For data-center projects, identify the transformer, generator, switchgear, UPS or riser route and its design requirements.
Confirm the body material, liner, fasteners and support interface as one assembly. Provide cable outside diameter, formation, peak and RMS short-circuit current, fault duration, proposed cleat spacing and mounting drawings for review.
Model-specific documents for engineering approval
Request the current model drawing, material information, installation instructions and test evidence applicable to the offered assembly. An IEC 61914 reference should be checked against the report’s sample and installation conditions. Confirm fire, smoke, halogen, UV and magnetic-permeability requirements separately where specified.
Plan your project RFQ
Send the model or drawing, actual cable outside diameter, arrangement, quantity and destination. Include the EPC document schedule and required delivery date. Younxin can review the supplied requirements before preparing a quotation.
Oil, gas and LNG cable routes
Corrosion exposure, cable-ladder interfaces, vertical retention and restraint evidence.
Oil and gas project guideData-center power distribution
Generator, transformer, UPS and switchgear feeder schedules with model-specific submittals.
Data-center project guideRequest a project cable-cleat quotation
Cable cleat applications and project requirements
The same trefoil arrangement can appear in very different operating environments. Use the following application checks to prepare a useful selection request. Final suitability depends on the offered model, supporting structure and project requirements.
Data-center power cable installation
For data centers, specify FF-T trefoil cable cleats against the power-cable schedule for transformer, generator, switchgear and UPS feeder routes where three single-core cables are installed in trefoil. Identify each circuit and its route so that cleat sizes and quantities can be reviewed against the actual layout.
Useful submission details include cable outside diameter, number of parallel circuits, tray or ladder arrangement, available mounting space, horizontal runs and vertical risers. Include the project short-circuit study and the proposed support locations. Redundant A and B supply routes should be identified in the drawings so the restraint proposal can be coordinated with the electrical design.
Ask for an assembly drawing, installation instructions and applicable mechanical test documentation. If the project specifies smoke, halogen or fire performance, request evidence for the relevant components and system. A stainless steel body description alone does not establish those properties.
Read the data-center cable-cleat selection guide.
Marine and shipboard cable installation
For marine cable installation, describe the vessel area and power-cable route: machinery spaces, electrical rooms, cable ladders, vertical runs or exposed deck sections have different service conditions. Include salt exposure, vibration or movement requirements, temperature, access for inspection and the support material in the enquiry.
Review the cleat body, liner and fasteners together. Cable-sheath compatibility and the contact between stainless steel hardware and the support structure need attention, particularly where moisture or dissimilar metals are present. Send the mounting drawing and project requirements for corrosion control, support retention and maintenance.
Where a shipyard or owner requires DNV, ABS or another classification approval, request the applicable certificate and check the manufacturer, exact model, scope and validity. Marine suitability cannot be established from a catalogue logo or material grade alone. Cable transits, bulkhead sealing and fire barriers remain separate parts of the installation.
Underground cable installation accessories
For underground power routes, FF-T cleats can be submitted for review on supported cable runs in tunnels, accessible trenches, shafts and cable chambers. Identify whether the cable is mounted on a ladder, bracket or other support, and provide the route drawing, cable dimensions and design loads.
Include the underground environment, drainage or flooding conditions, inspection access, cable bends, joints, terminations and transitions into vertical sections. Where the cable-system design requires thermal movement, identify that requirement so the restraint and support arrangement can be reviewed together. Cleats do not replace cable-pulling rollers or pulling equipment during installation.
This selection guidance concerns supported cables. It does not establish FF-T suitability for direct burial in soil, permanent immersion or a particular underground fire-performance class. Submit those conditions separately when they are part of the specification.
Oilfield, oil and gas power cable routes
For oilfield cable installation, identify the surface power route serving pump facilities, motor-control equipment, switchgear, utility systems or packaged electrical modules. For oil and gas, LNG or petrochemical projects, describe whether the route is inland, coastal, offshore or exposed to process chemicals.
Provide the corrosion specification, ambient conditions, cable-ladder details and access constraints alongside the electrical cable schedule. The material selection should cover the liner, closure parts and fixing hardware as well as the 316L body. Include vertical cable loads and the fault study where relevant to the route.
A cable cleat provides mechanical cable restraint; it does not provide the sealing function of a cable gland or establish hazardous-area approval for the electrical installation. If the project specifies ATEX, IECEx or another approval, identify the required equipment and scope in the document schedule. Downhole cables and well equipment require a separate product review.
Read the oil, gas and LNG cable-cleat guide.
Trefoil cable cleat selection questions
How do I select 316L trefoil cable cleats for cable ladder installation?
Start with the outside diameter of each single-core cable and select a matching FF-T catalogue size. Provide the cable ladder or tray drawing, rung dimensions, fixing details and available installation space so that the cleat and support interface can be reviewed together.
How is trefoil cable cleat spacing selected for short-circuit restraint?
Cleat spacing depends on the proposed assembly, cable formation and diameter, peak fault current, fault duration and the supporting structure. Send the short-circuit study and proposed layout for an engineering review; a test result at one spacing does not automatically apply at another.
What information is needed for vertical power cable riser cleats?
Identify the vertical run length, cable weight, support locations and fixing arrangement. Axial load retention and cable manufacturer requirements should be reviewed in addition to short-circuit restraint. Ask for evidence applicable to the selected assembly.
Can 316L stainless steel cable cleats be used on shipboard cable ladders?
FF-T cleats may be considered for supported trefoil power cables on shipboard routes. Submit exposure, vibration, liner and support details; verify any required class approval against the exact offered model and certificate scope.
How do I specify cable cleats for an underground cable tunnel?
Provide the tunnel cable schedule, cable outside diameters, trefoil circuit layout, support drawings, drainage conditions and project fire requirements. Review the mounting system and applicable test reports before selecting spacing. Direct burial and immersion require separate confirmation.