FF-T 316L Stainless Steel Trefoil Cable Cleats

FF-T 316L stainless steel trefoil cable cleats for specified oil, gas and data-center power routes. Select the size by cable outside diameter and confirm the restraint assembly, mounting and applicable test evidence.

Model
FF-T series (catalogue section: FF-T (ER))
Application
Trefoil power-cable restraint for data centers, shipboard routes, supported underground installations and oilfield surface facilities, subject to project review
Material
316L stainless steel body
Cable Outside Diameter Range
13–128 mm across the listed catalogue models; select by the individual model’s minimum and maximum cable outside diameter

Initial response within 1 hour during business hours.

Product specifications

SKUALI-1601812506195
ModelFF-T series (catalogue section: FF-T (ER))
ApplicationTrefoil power-cable restraint for data centers, shipboard routes, supported underground installations and oilfield surface facilities, subject to project review
Material316L stainless steel body
Cable Outside Diameter Range13–128 mm across the listed catalogue models; select by the individual model’s minimum and maximum cable outside diameter
Cable ArrangementThree single-core power cables in trefoil formation
Cleat DimensionsModel-specific height H and width W in mm; see the 24-model catalogue size table

FF-T 316L trefoil cable cleats for project power routes

The FF-T family is intended for three single-core cables in a trefoil formation. Match each cable’s actual outside diameter to the selected catalogue size and current drawing. The verified dimensional examples and company cable-cleat catalogue are provided below.

Review the liner, closure parts, mounting hole, fixing hardware and support arrangement with the quotation. The family code does not identify one size or one short-circuit rating.

Certifications and Test Reports Available

Younxin can provide certification and test documentation for project procurement and technical review.

DNV / ABS Approvals

Approval documentation is available for applicable cable-cleat models. Confirm the certificate scope for the proposed model with your quotation.

IEC 61914 Test Reports

STIEE short-circuit test reports are available for the tested trefoil and quad cable-cleat assemblies.

Intertek Test Reports

UV-aging and needle-flame test documentation is available for the stated sample models.

Certificates and complete test reports are provided on request. Confirm the covered model, assembly and installation conditions for your project.

Request certificates and test reports

Choose the cleat from the power-cable route

For oil and gas projects, identify process-plant, LNG utility, coastal-terminal or offshore-module exposure and send the corrosion specification with the electrical cable schedule. For data-center projects, identify the transformer, generator, switchgear, UPS or riser route and its design requirements.

Confirm the body material, liner, fasteners and support interface as one assembly. Provide cable outside diameter, formation, peak and RMS short-circuit current, fault duration, proposed cleat spacing and mounting drawings for review.

Model-specific documents for engineering approval

Request the current model drawing, material information, installation instructions and test evidence applicable to the offered assembly. An IEC 61914 reference should be checked against the report’s sample and installation conditions. Confirm fire, smoke, halogen, UV and magnetic-permeability requirements separately where specified.

Plan your project RFQ

Send the model or drawing, actual cable outside diameter, arrangement, quantity and destination. Include the EPC document schedule and required delivery date. Younxin can review the supplied requirements before preparing a quotation.

Oil, gas and LNG cable routes

Corrosion exposure, cable-ladder interfaces, vertical retention and restraint evidence.

Oil and gas project guide

Data-center power distribution

Generator, transformer, UPS and switchgear feeder schedules with model-specific submittals.

Data-center project guide

Request a project cable-cleat quotation

FF-T product specifications

Product identity and selection information
ItemSpecification or selection requirement
Product familyFF-T trefoil cable cleats; catalogue section titled FF-T (ER)
ManufacturerGuangzhou Yuanxin Industrial Holding Co., Ltd.
Body material316L stainless steel
Cable arrangementThree single-core power cables in trefoil formation
Size selectionIndividual catalogue models shown below, from FF-T1323 to FF-T119128; match actual cable outside diameter to the selected model
DimensionsHeight H and width W in millimetres; mounting details require the current model drawing
Liner and fixing assemblyConfirm liner material, closure parts, mounting hardware and support interface with the selected model
Installation spacing and torqueUse the approved project layout and model-specific installation instructions
Short-circuit performanceReview applicable test evidence for the exact assembly, cable diameter, formation, spacing and fault conditions
Project documentationRequest drawings, installation instructions, material information and applicable test reports with the RFQ

FF-T trefoil cable cleat size table

The following dimensions are transcribed from page 3 of the company cable-cleat catalogue. Cable diameter means the outside diameter of each cable, including its outer sheath. Use the cable manufacturer’s actual dimensions and tolerances; conductor cross-section alone does not select a cleat.

FF-T (ER) catalogue sizes — all dimensions in mm
Catalogue modelCable OD, min.–max.Height HWidth W
FF-T132313–237982
FF-T182318–237982
FF-T232823–288793
FF-T273227–329199
FF-T303530–3596103
FF-T333833–38101107
FF-T364236–42109116
FF-T404640–46118119
FF-T445044–50121126
FF-T485548–55130137
FF-T515851–58137143
FF-T556255–62141152
FF-T596659–66148161
FF-T637063–70156171
FF-T677467–74165180
FF-T717871–78168186
FF-T748274–82175195
FF-T778577–85180202
FF-T828882–88185208
FF-T889688–96199225
FF-T9610396–103210240
FF-T103111103–111224258
FF-T111119111–119237275
FF-T119128119–128265295

H and W follow the catalogue notation. The table is a dimensional selection reference, not a short-circuit rating table. Confirm the current drawing, liner configuration, mounting-hole dimensions, tolerances and fasteners before ordering. Where model ranges overlap, submit the actual cable and installation details for selection.

Selection example: a cable with a 52 mm outside diameter falls within the FF-T4855 catalogue range of 48–55 mm. Its listed H and W are 130 mm and 137 mm. This identifies a dimensional candidate; it does not establish the permitted spacing or fault duty of the installation.

Cable cleat applications and project requirements

The same trefoil arrangement can appear in very different operating environments. Use the following application checks to prepare a useful selection request. Final suitability depends on the offered model, supporting structure and project requirements.

Data-center power cable installation

For data centers, specify FF-T trefoil cable cleats against the power-cable schedule for transformer, generator, switchgear and UPS feeder routes where three single-core cables are installed in trefoil. Identify each circuit and its route so that cleat sizes and quantities can be reviewed against the actual layout.

Useful submission details include cable outside diameter, number of parallel circuits, tray or ladder arrangement, available mounting space, horizontal runs and vertical risers. Include the project short-circuit study and the proposed support locations. Redundant A and B supply routes should be identified in the drawings so the restraint proposal can be coordinated with the electrical design.

Ask for an assembly drawing, installation instructions and applicable mechanical test documentation. If the project specifies smoke, halogen or fire performance, request evidence for the relevant components and system. A stainless steel body description alone does not establish those properties.

Read the data-center cable-cleat selection guide.

Marine and shipboard cable installation

For marine cable installation, describe the vessel area and power-cable route: machinery spaces, electrical rooms, cable ladders, vertical runs or exposed deck sections have different service conditions. Include salt exposure, vibration or movement requirements, temperature, access for inspection and the support material in the enquiry.

Review the cleat body, liner and fasteners together. Cable-sheath compatibility and the contact between stainless steel hardware and the support structure need attention, particularly where moisture or dissimilar metals are present. Send the mounting drawing and project requirements for corrosion control, support retention and maintenance.

Where a shipyard or owner requires DNV, ABS or another classification approval, request the applicable certificate and check the manufacturer, exact model, scope and validity. Marine suitability cannot be established from a catalogue logo or material grade alone. Cable transits, bulkhead sealing and fire barriers remain separate parts of the installation.

Underground cable installation accessories

For underground power routes, FF-T cleats can be submitted for review on supported cable runs in tunnels, accessible trenches, shafts and cable chambers. Identify whether the cable is mounted on a ladder, bracket or other support, and provide the route drawing, cable dimensions and design loads.

Include the underground environment, drainage or flooding conditions, inspection access, cable bends, joints, terminations and transitions into vertical sections. Where the cable-system design requires thermal movement, identify that requirement so the restraint and support arrangement can be reviewed together. Cleats do not replace cable-pulling rollers or pulling equipment during installation.

This selection guidance concerns supported cables. It does not establish FF-T suitability for direct burial in soil, permanent immersion or a particular underground fire-performance class. Submit those conditions separately when they are part of the specification.

Oilfield, oil and gas power cable routes

For oilfield cable installation, identify the surface power route serving pump facilities, motor-control equipment, switchgear, utility systems or packaged electrical modules. For oil and gas, LNG or petrochemical projects, describe whether the route is inland, coastal, offshore or exposed to process chemicals.

Provide the corrosion specification, ambient conditions, cable-ladder details and access constraints alongside the electrical cable schedule. The material selection should cover the liner, closure parts and fixing hardware as well as the 316L body. Include vertical cable loads and the fault study where relevant to the route.

A cable cleat provides mechanical cable restraint; it does not provide the sealing function of a cable gland or establish hazardous-area approval for the electrical installation. If the project specifies ATEX, IECEx or another approval, identify the required equipment and scope in the document schedule. Downhole cables and well equipment require a separate product review.

Read the oil, gas and LNG cable-cleat guide.

How to select the cleat and mounting arrangement

  1. Confirm cable geometry. Supply actual outside diameter and tolerance for each cable, trefoil formation, circuit arrangement and the cable manufacturer’s installation requirements.
  2. Identify a dimensional candidate. Compare the FF-T catalogue range with the available space. Confirm the liner and mounting interface on the current model drawing.
  3. Provide the design loads. Submit peak and RMS short-circuit current and fault duration as separate values from the project study. Include vertical retention requirements where applicable.
  4. Review the supporting structure. Provide the ladder rung, tray, channel or bracket drawing, support material, mounting orientation and proposed cleat spacing.
  5. Match evidence to the assembly. Check the offered model, cable size, formation, fasteners, mounting surface and installation conditions against the applicable test documentation.
  6. Confirm the installation instructions. Obtain the approved spacing plan, fastening details and model-specific tightening instructions before site installation.

There is no universal spacing or tightening torque for the entire FF-T family. Bends, terminations, joints and transitions between horizontal and vertical runs need to be considered in the route design. Use an approved project arrangement rather than transferring another project’s spacing to a different installation.

IEC 61914 and model-specific test documentation

IEC 61914:2021 addresses requirements and testing for cable cleats and intermediate restraints. For procurement, an IEC reference should be accompanied by the report scope and the tested configuration relevant to the offered assembly.

Younxin’s quality-document register lists the following cable-cleat report references. These identify tested samples; they are not a declaration that every FF-T catalogue size has the same test results.

Report references for a model-specific document request
Test categorySample modelReport reference
Short-circuitYY-T240522ZAS01P04D31-06340
Short-circuitYY-Q334025ZAS01P04D33-47304-2
UV agingFF-T3035TSNT01480053
Needle-flameYY-T2405TSNT01481424

Request the complete report and documented correspondence between the commercial model being quoted and the tested sample. Short-circuit, UV-aging and needle-flame tests assess different characteristics. A needle-flame result does not establish the fire endurance of a complete power-cable system.

Request documents for your selected FF-T model.

Request a project cable-cleat quotation

Send the following information to help Younxin review the correct model and prepare an RFQ response:

  • Application: data center, shipboard, supported underground route, oilfield or another project environment.
  • Cable outside diameter in mm, cable data sheet, trefoil arrangement and quantity of circuits.
  • Preferred FF-T model, quantity, route or support drawing and proposed spacing.
  • Peak fault current in kA, RMS fault current in kA and fault duration in seconds, when available.
  • Mounting orientation, support material, liner requirements and fastener requirements.
  • Required reports, material records, marine approval or other project document requirements.
  • Delivery destination and required delivery date.

If the fault study or installation drawing is still being prepared, identify the missing information in the enquiry. A preliminary dimensional selection can then be distinguished from a completed technical review.

Send your cable schedule and request a quotation. You can also email info@younxin.com. Initial response within 1 hour during business hours.

Trefoil cable cleat selection questions

How do I select 316L trefoil cable cleats for cable ladder installation?

Start with the outside diameter of each single-core cable and select a matching FF-T catalogue size. Provide the cable ladder or tray drawing, rung dimensions, fixing details and available installation space so that the cleat and support interface can be reviewed together.

How is trefoil cable cleat spacing selected for short-circuit restraint?

Cleat spacing depends on the proposed assembly, cable formation and diameter, peak fault current, fault duration and the supporting structure. Send the short-circuit study and proposed layout for an engineering review; a test result at one spacing does not automatically apply at another.

What information is needed for vertical power cable riser cleats?

Identify the vertical run length, cable weight, support locations and fixing arrangement. Axial load retention and cable manufacturer requirements should be reviewed in addition to short-circuit restraint. Ask for evidence applicable to the selected assembly.

Can 316L stainless steel cable cleats be used on shipboard cable ladders?

FF-T cleats may be considered for supported trefoil power cables on shipboard routes. Submit exposure, vibration, liner and support details; verify any required class approval against the exact offered model and certificate scope.

How do I specify cable cleats for an underground cable tunnel?

Provide the tunnel cable schedule, cable outside diameters, trefoil circuit layout, support drawings, drainage conditions and project fire requirements. Review the mounting system and applicable test reports before selecting spacing. Direct burial and immersion require separate confirmation.

FF-T (ER) catalog sizes for your RFQ

Specify the cleat model as well as the cable outside diameter. These dimension references come from page 3 of the company cable-cleat catalog; the family product code alone does not select one of these sizes.

FF-T (ER) trefoil cleat model examples — dimensions in mm
Catalog modelCable diameter, min.–max.Height HWidth W
FF-T404640–46118119
FF-T445044–50121126
FF-T485548–55130137
FF-T778577–85180202
FF-T119128119–128265295

Use the catalog’s H and W notation when checking the installation space. Confirm the mounting hole, liner, hardware and current model drawing with the quotation. Short-circuit evidence must identify the proposed model, cable arrangement, spacing and test conditions.

Download the company cable-cleat catalog (PDF) — see page 3 for the FF-T (ER) table and the other pages for single, trefoil and quad arrangements.

FAQ

Project selection questions

How do I select an FF-T trefoil size?

Use the outside diameter of each of the three cables and the current model drawing. The catalogue examples below identify individual FF-T sizes, height and width. Confirm the liner and mounting details with the RFQ.

Where can FF-T cleats be considered in oil, gas and data-center projects?

Submit the specified process-plant, terminal, generator, transformer, switchgear or UPS power route for review. Include the site environment, cable arrangement, fault duty and support drawings.

Does the FF-T family name establish a short-circuit rating?

The proposed size and complete assembly need evidence applicable to the cable diameter, formation, spacing, mounting surface and fault conditions. Request the report and documented correspondence for the quoted model.

What should I send for an export project quotation?

Send the selected FF-T size or drawing, cable outside diameter, quantity, destination and required date. Add the EPC submittal list, material requirements and fault data when available.