What drawing is needed for a custom cable-cleat layout?
Provide a cross-section showing each cable’s outside diameter, positions and centre distances, together with the support and fixing dimensions.

316L stainless steel cable-cleat selection for drawing-defined power-cable layouts. Send each cable’s outside diameter, formation, mounting drawing and required project documents for review.
SKU: ALI-1601812463564
Initial response within 1 hour during business hours.
Specifications for the selected model are available on request. Send your model or drawing, required dimensions and quantity so we can confirm the product details before quotation.
Send a cross-section drawing showing every cable, its outside diameter and cable-to-cable spacing. Identify the required single, trefoil or four-cable arrangement and any different neutral-cable diameter.
For four-cable layouts, specify the exact positions and support interface. Request the model drawing, liner and fixing details, and evidence applicable to that arrangement before final selection.
Younxin can provide certification and test documentation for project procurement and technical review.
Approval documentation is available for applicable cable-cleat models. Confirm the certificate scope for the proposed model with your quotation.
STIEE short-circuit test reports are available for the tested trefoil and quad cable-cleat assemblies.
UV-aging and needle-flame test documentation is available for the stated sample models.
Certificates and complete test reports are provided on request. Confirm the covered model, assembly and installation conditions for your project.
For oil and gas projects, identify process-plant, LNG utility, coastal-terminal or offshore-module exposure and send the corrosion specification with the electrical cable schedule. For data-center projects, identify the transformer, generator, switchgear, UPS or riser route and its design requirements.
Confirm the body material, liner, fasteners and support interface as one assembly. Provide cable outside diameter, formation, peak and RMS short-circuit current, fault duration, proposed cleat spacing and mounting drawings for review.
Request the current model drawing, material information, installation instructions and test evidence applicable to the offered assembly. An IEC 61914 reference should be checked against the report’s sample and installation conditions. Confirm fire, smoke, halogen, UV and magnetic-permeability requirements separately where specified.
Send the model or drawing, actual cable outside diameter, arrangement, quantity and destination. Include the EPC document schedule and required delivery date. Younxin can review the supplied requirements before preparing a quotation.
Corrosion exposure, cable-ladder interfaces, vertical retention and restraint evidence.
Oil and gas project guideGenerator, transformer, UPS and switchgear feeder schedules with model-specific submittals.
Data-center project guideProvide a cross-section showing each cable’s outside diameter, positions and centre distances, together with the support and fixing dimensions.
Identify all four cable positions and functions, including any different neutral-cable diameter. Add the required liner, closure and mounting details.
Request a documented review of the proposed assembly against the tested sample and installation. Formation, diameter, spacing and support differences need to be addressed before approval.
Send the drawing, material requirement, quantities and delivery destination. Include the fault study, installation orientation and required project documents for technical review.